Customization: | Available |
---|---|
Function: | Thermal Oil Boiler |
Fuel: | Gas-Fired |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
The thermal oil boiler adopts circulating pump to press the oil circular flow inside boiler, and transfer the heat to other equipment, and when the heat was released, the fluid oil will back into heater through circulating pump to absorb heat and re-transfer the heat to other equipment, in this cyclic operation, the thermal oil boiler finish heat transfer.
Industrial using application: asphalt industry, rubber industry, lubricant industry, chemical industry, food industry, oil industry, drying and other industries, etc.
Main Technology Application
1. It adopts a wet-back internal combustion two-pass structure, and the top of the boiler is equipped with a top coil, which effectively prevents the flame from directly radiating to the rear wall. At the same time, under the premise of a compact structure, it increases the radiation heating area and improves the thermal efficiency of the boiler.
2. The use of micro-positive pressure operation effectively improves the combustion intensity of the furnace, makes the volume of the boiler with the same capacity smaller, eliminates the air leakage of the boiler furnace and flue, and improves the thermal efficiency of the boiler.
3. Adopt advanced EDA technology to calculate the size of the furnace body and the flow rate of flue gas in detail, and make full use of flame and flue gas heat exchange to ensure reliable operation and sufficient cooling of the boiler, and improve the thermal efficiency of the boiler.
4. The high-efficiency condensation technology is adopted to effectively reduce the exhaust gas temperature and improve the thermal efficiency of the boiler.
5. Reasonable structural design and excellent refractory and heat preservation materials are adopted to greatly reduce the external temperature of the furnace body, making the external temperature lower than 50 degrees (higher than the national standard), reducing heat loss and improving the thermal efficiency of the boiler.
6. It adopts a new design to reduce the emission of harmful substances during fuel combustion and meet the national environmental protection standards, especially to reduce the emission of nitrogen oxides and meet the national low nitrogen emission standards.
7. Imported burners of many well-known international brands are used to adapt to various application scenarios, ensuring quality and safety.
8. Adopt PLC and other automation controllers of international brands such as Siemens as the control core, and also use peripheral components of international brands to realize a high-quality fully automatic control system, which can collect various import and export temperatures, pressures, etc. in real time. The parameters are displayed centrally in the control cabinet in real time. Through the closed-loop control system such as PID, the boiler is guaranteed to work stably under various parameters set by the user. At the same time, the working range of the data is monitored, and various abnormalities are reminded or alarmed, which is convenient for users. use and maintenance. The control module also has powerful expansion capabilities, and can conveniently realize various in-depth applications such as group control and remote control according to customer needs.
Technical Parameter
Product model detail code: YY(Q)W- Rated heating capacity (KW) Y(Q) | |||||||||||
Rated heating capacity | KW | 120 | 240 | 350 | 500 | 700 | 1000 | 1200 | 1400 | 2000 | 2400 |
X104Kcal/h | 10 | 20 | 30 | 40 | 60 | 80 | 100 | 120 | 160 | 200 | |
Thermal efficiency(≥%) | Y | 96.10 | 96.09 | 96.28 | 96.27 | 96.02 | 96.00 | 96.06 | 95.03 | 96.07 | 96.06 |
Q | 98.05 | 98.04 | 98.23 | 98.20 | 98.53 | 98.52 | 98.16 | 98.53 | 98.55 | 98.50 | |
Design pressure (MPa) | 1.1 | ||||||||||
Maximum temperature of medium (ºC) | 320 | ||||||||||
Circulating oil flow rate (m3/h) | 12.5 | 18 | 30 | 30 | 60 | 80 | 100 | 100 | 160 | 160 | |
Oil content of furnace (m3) | 0.09 | 0.12 | 0.29 | 0.38 | 0.52 | 0.57 | 0.74 | 0.92 | 1.55 | 1.77 | |
Pipe connection inner diameter (DN) | 50 | 50 | 65 | 65 | 100 | 100 | 150 | 150 | 150 | 150 | |
Total system installed capacity (KW) | 4.7 | 7.2 | 9.5 | 9.8 | 17.6 | 18.0 | 25.7 | 26.5 | 41.0 | 53.5 | |
Dimensions of transport(mm) | L | 2180 | 2514 | 2769 | 3250 | 3540 | 3764 | 4374 | 5410 | 5640 | 5560 |
W | 1290 | 1320 | 1650 | 1690 | 1710 | 1810 | 1810 | 1810 | 2022 | 2254 | |
H | 1575 | 1575 | 1993 | 2082 | 1880 | 2291 | 2321 | 2321 | 2480 | 2700 | |
Total weight of equipment(Kg) | 1550 | 1632 | 2745 | 3146 | 3771 | 4496 | 4993 | 5680 | 7700 | 8765 | |
Rated heating capacity | KW | 3000 | 3500 | 4100 | 4700 | 6000 | 7000 | 8200 | 9300 | 12000 | --- |
X104Kcal/h | 250 | 300 | 350 | 400 | 500 | 600 | 700 | 800 | 1000 | --- | |
Thermal efficiency(≥%) | 96.00 | 96.10 | 96.01 | 96.20 | 96.18 | 96.17 | 92.98 | 96.06 | 96.11 | --- | |
98.02 | 98.03 | 98.06 | 98.07 | 98.04 | 98.08 | 92.15 | 98.39 | 98.05 | --- | ||
Design pressure(MPa) | 1.1 | ||||||||||
Maximum temperature of medium(ºC) | 320 | ||||||||||
Circulating oil flow rate(m3/h) | 180 | 200 | 250 | 250 | 350 | 400 | 350 | 500 | 600 | --- | |
Oil content of furnace(m3) | 1.96 | 3.78 | 4.61 | 5.70 | 7.40 | 8.35 | 9.50 | 10.20 | 13.30 | --- | |
Inner diameter of piping connection(DN) | 150 | 200 | 200 | 250 | 250 | 250 | 300 | 300 | 300 | --- | |
Total installed capacity of the system(KW) | 77.2 | 87.2 | 111.7 | 120.2 | 164.2 | 165 | 202 | 198 | 200 | --- | |
Dimensions of transport(mm) | L | 6194 | 6674 | 7456 | 7742 | 8990 | 9441 | 10484 | 10966 | --- | |
W | 2254 | 2610 | 2807 | 3240 | 3406 | 3390 | 3560 | 3610 | --- | ||
H | 2700 | 3150 | 3402 | 3860 | 4117 | 4107 | 4230 | 4280 | --- | ||
Total weight of equipment(Kg) | 10267 | 16743 | 17446 | 20669 | 29682 | 32311 | 34640 | 36852 | 49380 | --- | |
Note 1. All the above values are calculated based on the low heat value of 8400kcal/Nm for natural gas and 10250kcal/kg for diesel. Note 2. Due to the need of continuous improvement, the company reserves the right to modify the appearance and size specifications, the above parameters are for reference only, please refer to the final drawing. Note 3. Y: fuel oil Q: gas |
Company Profile
No. |
Industry |
usage |
1 |
Chemical industry |
polymerization industry,oil industry,reaction tank,distillation,enrichment, oil chemical industry, industry, polymerization reaction cans, distillation, concentration |
2 |
Plastic industry |
plastic foam and squeeze to finalize the design, |
3 |
Textile industry |
resin stenters,dyeing machine and the dry room,high temperature machine,roller |
4 |
Rubber industry |
cooking,dry,vegetable oil refining |
5 |
Wood industry |
heating to finalize the design of chipboard,sandwich plate,wamu board,fiber |
6 |
Paper industry |
multi-layer cardboard of packed carton box,dying and desiccation |
7 |
Others |
heating of metal electroplating slot,coating condensation,drying,distillation of pharmaceutical industry,reduction,concentration,dehydration,air conditioning industry,etc |